PCR PLATE CENTRIFUGE - Lab-Wissen

Search our Site
Go to content

Main menu:

PCR PLATE CENTRIFUGE

PRODUCTS > Sample Preparation > Centrifuges > PCR Plate Centrifuge
BENCHTOP CENTRIFUGE:

Plate Centrifuge | Model PlateSpin3
FEATURES:
Handy spin-down of several plate types including PCR and deep-well plates
  • This model is especially efficient at removing air bubbles from wells or water droplets from plate walls

Easy to use thanks to the swing rotor
  • Plates can be set easily simply by placing them in the bucket.
  • Because plates do not need to be set vertically, liquid leakage is not a concern.

The unit can accommodate different options at a time
  • 2 x 96-hole PCR plates
  • 6 x microplates
  • 2 x deep-well plates

Two-Second Imbalance Detector
  • Approximately 2 seconds after the start of centrifugation
  • It detects abnormal vibration and alerts that there is an imbalance

Rapid and simple spin-down with the memory flashing function
  • The rotor rotates only while the START key is pressed.

Various beep sounds can be selected depending on your preference
  • The operation completion beep can be selected from 11 types including mute
  • Four volume levels are available

Compliant with International Safety Requirements IEC61010-2-020
  • This model has been designed to ensure user safety by retaining fragments within the centrifuge if the rotor brakes during centrifugation
TECHNICAL SPECIFICATIONS:
Rotor Type:
  • Swing Rotor
Maximum Capacity:
  • 2x Deep-Well plate
  • 6×micro plate
Maximum Speed:
  • 3700 rpm
Maximum RCF (xg):
  • 1530 xg
Dimensions:
  • Width: 34 cm
  • Depth: 42 cm
  • Height: 33 cm (Closed Lid) & 66 cm (Open Lid)
Weight:
  • 20 kg
Power Consumption:
  • 120W; 0.44MJ/h (Power-saving mode: ~7W)
Power Requirements:
  • Single phase 220/230V ±10%, 50/60Hz, 5A
  • Single phase 110/115V ±10%, 50/60Hz, 8A
Rated Voltage / Current:
  • 110V 2.7A; 115V 2.0A; 220/230V 1.0A
Ambient Conditions:
  • Temperature: 10 - 35°C;
  • Humidity: 30 - 85%
  • Atmospherics Pressure: 70 - 106 kPa (700 - 1,060 mbar)
Conforming Standard:
  • IEC 61010-2-020
Speed Setting Range:
  • 200 - 3700 rpm
  • 10 rpm Step
Timer Setting Range:
  • Seconds: 1 second step
  • Minutes: 1 minute step
  • Hour: 1 hour step
  • Hold
Program Memory:
  • 99 Channels at the maximum
  • 3 for Direct Invocation using the Panel Button
Acceleration / Deceleration:
  • 2 Ways of Switching
DOWNLOAD AREA:
(1) Download English Leaflet:

(EN; 4.2 MB)
 
Back to content | Back to main menu